- Average Probability of Failure on Demand (PFDavg) 2.82 x 10-4 (Tproof = 1 year), 4.63 x 10-4 (Tproof = 2 years), 1.00 x 10-3 (Tproof = 5 years), дополнительные сведения в руководстве по технике безопасности
- Demand mode High
- Demand rate 3 000 s
- Demand response time Signal input: < 0.5 s (opto output), Temperature input: < 1.1 s (opto output)
- Description of the "safe state" analogue Output ≤ 3.6 mA or output ≥ 21 mA, de-energized (relay output)
- Diagnostic test interval 30 s
- Mean Time To Repair (MTTR) 24 h
- MTBF 74 Years
- Relay lifetime 100000 times
- Safe Failure Fraction (SFF) 93 %
- SIL PAPER SIL certificate
- Total failure rate for dangerous detected failures (λDD) 352 FIT
- Total failure rate for dangerous undetected failures (λDU) 43 FIT
- Total failure rate for safe detected failures (λSD) 0 FIT
- Total failure rate for safe undetected failures (λSU) 278 FIT
- Tproof 4 Years
- Брошюра / каталог CAT 4.1 ELECTR 16/17 EN
- Вероятность отказа в час PFH 4.33 x 10-8 h-1
- Вид защиты IP20
- Вид соединения Винтовое соединение, Съемный клеммный блок
- Влажность 0...95 % (без появления конденсата)
- Влияние сопротивления нагрузки ≤ 0.01% на контакте / 100 Ω
- Входное сопротивление возможность конфигурирования, 0…10 kΩ
- Входное сопротивление, напряжение > 10 MОм @ 600 мВ, 2 МОм @ 28 В
- Входное сопротивление, ток 20 Ом + PTC 50 Ом
- Входной ток 0...20 mA, 4...20 mA
- Высота 117,2 мм
- Выходной ток 0…23 мA, конфигурируемый: 0…20 / 4…20 / 20…0 / 20…4 мA, возможность конфигурирования — уменьшение (3,5 мА) / увеличение (23 мА) @ ошибке
- Глубина 113,6 мм
- Глубина (дюймов) 4,472 inch
- Датчик 2-/3-/4-проводной, RTD: PT10, PT20, PT50, PT100, PT250, PT300, PT400, PT500, PT1000, Ni50, Ni100, Ni120, Ni1000, Термоэлемент: B, E, J, K, N, R, S, T ; в соответствии с IEC 60584-1 и L, U в соответствии с DIN43710, Потенциометр, Сопротивление: 0–12 кОм
- Диапазон зажима, макс. 2,5 mm²
- Диапазон зажима, мин. 0,5 mm²
- Диапазон размеров зажимаемых проводников, измерительное соединение, 2,5 mm²
- Исполнение EX-преобразователь сигналов, Выход Ex: U, I, R,ϑ, Безоп. выход: 4-20 мА/реле, 1-канальн.
- Категория безопасности SIL 2
- Конфигурация с программным обеспечением FDT/DTM
- Макс выход 3.8…20.5 мA / 0…20.5 мA (в зависимости от линейки)
- Масса нетто 202 g
- Момент затяжки, макс. 0,6 Nm
- Момент затяжки, мин. 0,4 Nm
- Мощность ≤ 500 ВA / 60 Вт (защищенная зона),≤ 16 ВA / 32 Вт (Зона 2)
- Мощность P0 40 mW
- Напряжение возможность конфигурирования, 0…1 V DC, 0,2…1 V DC, 1…5 V DC, 0...(5)10 V, 2…10 V DC
- Напряжение U0 8.7 В DC
- Напряжение питания 19,2…31,2 В DC
- Напряжение развязки 2 кВ, вход / выход / питание
- Непрерывный ток ≤ 0,5 A AC / 0,3 A DC (безопасная зона), ≤ 0,5 A AC / 1 A DC (зона 2)
- Номинальное рабочее напряжение ≤ 250 В AC / 30 В DC (взрывозащенная область),≤ 32 В AC / 32 В DC (Зона 2)
- Норма упаковки (VPE) 1 Шт.
- Нормы по ЭМС DIN EN 61326, NE 21
- Обозначение II (1) G [Ex ia Ga] IIC/IIB/IIA, I (M1) [Ex ia Ma] I, II (1) G [Ex ia Ga] IIC, II (1) D [Ex ia Da] IIIC
- Одобрение / сертификат / документ о соответствии SIL certificate Certification DNV GL Declaration of Conformity
- Отказоустойчивость оборудования (HFT) 0
- Пользовательская документация Instruction sheet Manual MAN SAFETY ACT20X-HUI-SAO
- Поперечное сечение подключаемого провода AWG, макс. AWG 14
- Поперечное сечение подключаемого провода AWG, мин. AWG 30
- Потенциометр 10 Ом…10 кОм
- Потребляемая мощность ≤ 2,1 Вт
- Программное обеспечение WI-Manager, DTM-Library for online installation V.1.2.0
- Рабочая температура -20 °C...60 °C
- Рабочая температура, макс. 60 °C
- Рабочая температура, мин. -20 °C
- Расчетное напряжение 300 В
- Сведения об изделии Для этого устройства компания Weidmüller предоставляет увеличенный гарантийный период (36 месяцев).
- Сертификат ATEX 10ATEX0071X.pdf
- Сертификат IECEx IECEx certification
- Сертификат UL E337701.pdf
- Сертификат № (ATEX) KEMA10ATEX0071X
- Сертификат № (IECEX) IECEXKEM10.0034X
- Сопротивление линии в измерительной цепи ≤ 50 Ω
- Сопротивление нагрузки, ток ≤ 600 Ом
- Степень загрязнения 2
- Текст описания, длинный Универсальный измерительный преобразователь с гальванической развязкой и максимальный выключатель для сигналов термометров сопротивления RTD/ термопар TC и DC-сигналов по току и напряжению для применения во взрывоопасных зонах Ex,1-канальный измерительный преобразователь с гальванической развязкой и максимальный выключатель с монтажной шириной 22,5 мм и внешним электропитанием,,для регистрации и разделения сигналов датчиков термометров сопротивления RTD/термопар TC, сопротивлений, потенциометров, а также DC-сигналов по току,0(4)...20 мА и напряжению 0...12 В из взрывоопасных Ex-зон 0, 1, 2. Питание датчикам можно подавать через токовую петлю,0...20 мА.,В безопасной области выход, по выбору, можно использовать как активный сигнальный 0(4)...20 мА или как пассивный - 4...20 мА,токовая петля. На выходе предоставляется релейный контакт (нормально разомкнутый) для контроля предельного значения,Сообщения о состоянии/неисправностях выдаются через релейный контакт (нормально разомкнутый).,Предусмотрена возможность конфигурирования модуля при помощи стандартного программного обеспечения FDT/DTM.Корпус для установки в ряд на монтажную рейку TS35,Размеры: Д/Ш/В 119,2/ 22,5/ 113,6,Технология винтового соединения/ номинальная площадь поперечного сечения 2,5 мм2,Степень защиты: IP 20 ,,ВходТермометр сопротивления: PT100, PT500, PT1000, Ni50, Ni100, Ni120, Ni1000, Сопротивление 0...10 кОм / Потенциометр 10 Ом... 10 кОм,Термопара типа: B, E, J, K, N, R, S, T, U, L, 0(4)...20 мА, 0...12 В/ 2...10 В,Электропитание датчика 28...16,5 В DC / 0...20 мА,Выход, активный 0(4)...20 мА / 20..0 мА, конфигурируемый, пассивный - 4...20 мА токовая петля 3,5...26 В DC,Полное сопротивление нагрузки< 600 Ohm,Выход аварийной сигнализации - реле 1 нормально разомкнутый контакт, 250 В AC / 30 В DC @ 2 A, безопасная область, 32 В AC @ 0,5 A/ 32 В DC @ 1 A, зона 2,Точность < 0,1 % v.E,Температурный коэффициент < 0,01% v.E./°C (Tu),Выход аварийной сигнализации - реле 1 нормально разомкнутый контакт, 250 В AC / 30 В DC @ 2 A, безопасная область, 32 В AC @ 0,5 A/ 32 В DC @ 1, A зона 2,Электропитание 19...31,2 В DC,Мощность потерь ок. 3,5 Вт,Диапазон температур,окружающей среды -20 °C...+60 °C Надежная развязка EN 61010, 3-канальная гальваническая развязка 2,6 кВ AC/DC всех цепей относительно друг друга,Рабочее напряжение 300 В AC/DC при категории перенапряжения II и классе загрязнения 2,Сертификаты cULus, ATEX IECEX, FM,,ATEX-маркировка II 3 G ExnA nC IIC T4,ATEX- данные U0 = 8,7 В DC, I0 = 18,4 мА DC, P0 = 40 мВт,,Тип ACT20X-HUI-SAO-S
- Текст описания, сокращенный Универсальный измерительный преобразователь и максимальный выключатель, для сигналов термометров сопротивления RTD/термопар TC и , DC-сигналов по току/напряжению для применения во взрывоопасных зонах Ex,1-канальный измерительный преобразователь и максимальный выключатель с монтажной шириной 22,5 мм и внешним электропитанием,, для регистрации и гальванической развязки сигналов термометров сопротивления RTD / термопар TC, сопротивлений, потенциометров, а также DC- сигналов по току, 0(4)...20 мА и напряжению 0...12 В их Ex-зон 0, 1, 2. Питание датчиков может осуществляться через токовую петлю , 0...20 мА., В безопасной области выход, по выбору, можно использовать как активный сигнальный 0(4)...20 мА или как пассивный - токовая петля , 4...20 мА. На выходе имеется релейный контакт (нормально разомкнутый) для контроля предельного значения., Сообщения о состоянии/ ошибках подаются через релейный (нормально разомкнутый) контакт., Предусмотрена возможность конфигурирования модуля при помощи стандартного программного обеспечения FDT/DTM.
- Температура в области входа регулируется в пределах -200...+800 ℃
- Температура хранения -20 °C...85 °C
- Температура хранения, макс. 85 °C
- Температура хранения, мин. -20 °C
- Технические данные EPLAN, WSCAD
- Тип Реле, 1 нормально замкнутый контакт (беспотенциальный)
- Тип изделия Преобразователь сигналов
- Тип устройства B
- Ток I0 18.4 мA
- Уровень мощности ≤ 62.5 ВA / 32 Вт (защищенная зона),≤ 16 ВA / 32 Вт (Зона 2)
- Функциональность Программируемые переключатели, Ошибка датчика, Оконная функция
- Функция аварийной сигнализации Отсутствует напряжение питания, Ошибка устройства
- Номер для заказа 8965490000
- Ширина 22,5 мм
Последние
TOP
TOP
TOP
TOP
TOP
TOP
TOP
TOP
TOP
TOP
TOP
TOP
TOP
TOP
TOP
TOP
TOP
TOP
TOP
TOP
TOP
TOP
TOP
TOP
TOP
TOP
TOP
TOP
TOP
TOP
Общие данные | |
Average Probability of Failure on Demand (PFDavg) | 2.82 x 10-4 (Tproof = 1 year), 4.63 x 10-4 (Tproof = 2 years), 1.00 x 10-3 (Tproof = 5 years), дополнительные сведения в руководстве по технике безопасности |
Demand mode | High |
Demand rate | 3 000 s |
Demand response time | Signal input: < 0.5 s (opto output), Temperature input: < 1.1 s (opto output) |
Description of the "safe state" | analogue Output ≤ 3.6 mA or output ≥ 21 mA, de-energized (relay output) |
Diagnostic test interval | 30 s |
Mean Time To Repair (MTTR) | 24 h |
MTBF | 74 Years |
Relay lifetime | 100000 times |
Safe Failure Fraction (SFF) | 93 % |
SIL PAPER | SIL certificate |
Total failure rate for dangerous detected failures (λDD) | 352 FIT |
Total failure rate for dangerous undetected failures (λDU) | 43 FIT |
Total failure rate for safe detected failures (λSD) | 0 FIT |
Total failure rate for safe undetected failures (λSU) | 278 FIT |
Tproof | 4 Years |
Брошюра / каталог | CAT 4.1 ELECTR 16/17 EN |
Вероятность отказа в час PFH | 4.33 x 10-8 h-1 |
Вид защиты | IP20 |
Вид соединения | Винтовое соединение, Съемный клеммный блок |
Влажность | 0...95 % (без появления конденсата) |
Влияние сопротивления нагрузки | ≤ 0.01% на контакте / 100 Ω |
Входное сопротивление | возможность конфигурирования, 0…10 kΩ |
Входное сопротивление, напряжение | > 10 MОм @ 600 мВ, 2 МОм @ 28 В |
Входное сопротивление, ток | 20 Ом + PTC 50 Ом |
Входной ток | 0...20 mA, 4...20 mA |
Высота | 117,2 мм |
Выходной ток | 0…23 мA, конфигурируемый: 0…20 / 4…20 / 20…0 / 20…4 мA, возможность конфигурирования — уменьшение (3,5 мА) / увеличение (23 мА) @ ошибке |
Глубина | 113,6 мм |
Глубина (дюймов) | 4,472 inch |
Датчик | 2-/3-/4-проводной, RTD: PT10, PT20, PT50, PT100, PT250, PT300, PT400, PT500, PT1000, Ni50, Ni100, Ni120, Ni1000, Термоэлемент: B, E, J, K, N, R, S, T ; в соответствии с IEC 60584-1 и L, U в соответствии с DIN43710, Потенциометр, Сопротивление: 0–12 кОм |
Диапазон зажима, макс. | 2,5 mm² |
Диапазон зажима, мин. | 0,5 mm² |
Диапазон размеров зажимаемых проводников, измерительное соединение, | 2,5 mm² |
Исполнение | EX-преобразователь сигналов, Выход Ex: U, I, R,ϑ, Безоп. выход: 4-20 мА/реле, 1-канальн. |
Категория безопасности | SIL 2 |
Конфигурация | с программным обеспечением FDT/DTM |
Макс выход | 3.8…20.5 мA / 0…20.5 мA (в зависимости от линейки) |
Масса нетто | 202 g |
Момент затяжки, макс. | 0,6 Nm |
Момент затяжки, мин. | 0,4 Nm |
Мощность | ≤ 500 ВA / 60 Вт (защищенная зона),≤ 16 ВA / 32 Вт (Зона 2) |
Мощность P0 | 40 mW |
Напряжение | возможность конфигурирования, 0…1 V DC, 0,2…1 V DC, 1…5 V DC, 0...(5)10 V, 2…10 V DC |
Напряжение U0 | 8.7 В DC |
Напряжение питания | 19,2…31,2 В DC |
Напряжение развязки | 2 кВ, вход / выход / питание |
Непрерывный ток | ≤ 0,5 A AC / 0,3 A DC (безопасная зона), ≤ 0,5 A AC / 1 A DC (зона 2) |
Номинальное рабочее напряжение | ≤ 250 В AC / 30 В DC (взрывозащенная область),≤ 32 В AC / 32 В DC (Зона 2) |
Норма упаковки (VPE) | 1 Шт. |
Нормы по ЭМС | DIN EN 61326, NE 21 |
Обозначение | II (1) G [Ex ia Ga] IIC/IIB/IIA, I (M1) [Ex ia Ma] I, II (1) G [Ex ia Ga] IIC, II (1) D [Ex ia Da] IIIC |
Одобрение / сертификат / документ о соответствии | SIL certificate Certification DNV GL Declaration of Conformity |
Отказоустойчивость оборудования (HFT) | 0 |
Пользовательская документация | Instruction sheet Manual MAN SAFETY ACT20X-HUI-SAO |
Поперечное сечение подключаемого провода AWG, макс. | AWG 14 |
Поперечное сечение подключаемого провода AWG, мин. | AWG 30 |
Потенциометр | 10 Ом…10 кОм |
Потребляемая мощность | ≤ 2,1 Вт |
Программное обеспечение | WI-Manager, DTM-Library for online installation V.1.2.0 |
Рабочая температура | -20 °C...60 °C |
Рабочая температура, макс. | 60 °C |
Рабочая температура, мин. | -20 °C |
Расчетное напряжение | 300 В |
Сведения об изделии | Для этого устройства компания Weidmüller предоставляет увеличенный гарантийный период (36 месяцев). |
Сертификат ATEX | 10ATEX0071X.pdf |
Сертификат IECEx | IECEx certification |
Сертификат UL | E337701.pdf |
Сертификат № (ATEX) | KEMA10ATEX0071X |
Сертификат № (IECEX) | IECEXKEM10.0034X |
Сопротивление линии в измерительной цепи | ≤ 50 Ω |
Сопротивление нагрузки, ток | ≤ 600 Ом |
Степень загрязнения | 2 |
Текст описания, длинный | Универсальный измерительный преобразователь с гальванической развязкой и максимальный выключатель для сигналов термометров сопротивления RTD/ термопар TC и DC-сигналов по току и напряжению для применения во взрывоопасных зонах Ex,1-канальный измерительный преобразователь с гальванической развязкой и максимальный выключатель с монтажной шириной 22,5 мм и внешним электропитанием,,для регистрации и разделения сигналов датчиков термометров сопротивления RTD/термопар TC, сопротивлений, потенциометров, а также DC-сигналов по току,0(4)...20 мА и напряжению 0...12 В из взрывоопасных Ex-зон 0, 1, 2. Питание датчикам можно подавать через токовую петлю,0...20 мА.,В безопасной области выход, по выбору, можно использовать как активный сигнальный 0(4)...20 мА или как пассивный - 4...20 мА,токовая петля. На выходе предоставляется релейный контакт (нормально разомкнутый) для контроля предельного значения,Сообщения о состоянии/неисправностях выдаются через релейный контакт (нормально разомкнутый).,Предусмотрена возможность конфигурирования модуля при помощи стандартного программного обеспечения FDT/DTM.Корпус для установки в ряд на монтажную рейку TS35,Размеры: Д/Ш/В 119,2/ 22,5/ 113,6,Технология винтового соединения/ номинальная площадь поперечного сечения 2,5 мм2,Степень защиты: IP 20 ,,ВходТермометр сопротивления: PT100, PT500, PT1000, Ni50, Ni100, Ni120, Ni1000, Сопротивление 0...10 кОм / Потенциометр 10 Ом... 10 кОм,Термопара типа: B, E, J, K, N, R, S, T, U, L, 0(4)...20 мА, 0...12 В/ 2...10 В,Электропитание датчика 28...16,5 В DC / 0...20 мА,Выход, активный 0(4)...20 мА / 20..0 мА, конфигурируемый, пассивный - 4...20 мА токовая петля 3,5...26 В DC,Полное сопротивление нагрузки< 600 Ohm,Выход аварийной сигнализации - реле 1 нормально разомкнутый контакт, 250 В AC / 30 В DC @ 2 A, безопасная область, 32 В AC @ 0,5 A/ 32 В DC @ 1 A, зона 2,Точность < 0,1 % v.E,Температурный коэффициент < 0,01% v.E./°C (Tu),Выход аварийной сигнализации - реле 1 нормально разомкнутый контакт, 250 В AC / 30 В DC @ 2 A, безопасная область, 32 В AC @ 0,5 A/ 32 В DC @ 1, A зона 2,Электропитание 19...31,2 В DC,Мощность потерь ок. 3,5 Вт,Диапазон температур,окружающей среды -20 °C...+60 °C Надежная развязка EN 61010, 3-канальная гальваническая развязка 2,6 кВ AC/DC всех цепей относительно друг друга,Рабочее напряжение 300 В AC/DC при категории перенапряжения II и классе загрязнения 2,Сертификаты cULus, ATEX IECEX, FM,,ATEX-маркировка II 3 G ExnA nC IIC T4,ATEX- данные U0 = 8,7 В DC, I0 = 18,4 мА DC, P0 = 40 мВт,,Тип ACT20X-HUI-SAO-S |
Текст описания, сокращенный | Универсальный измерительный преобразователь и максимальный выключатель, для сигналов термометров сопротивления RTD/термопар TC и , DC-сигналов по току/напряжению для применения во взрывоопасных зонах Ex,1-канальный измерительный преобразователь и максимальный выключатель с монтажной шириной 22,5 мм и внешним электропитанием,, для регистрации и гальванической развязки сигналов термометров сопротивления RTD / термопар TC, сопротивлений, потенциометров, а также DC- сигналов по току, 0(4)...20 мА и напряжению 0...12 В их Ex-зон 0, 1, 2. Питание датчиков может осуществляться через токовую петлю , 0...20 мА., В безопасной области выход, по выбору, можно использовать как активный сигнальный 0(4)...20 мА или как пассивный - токовая петля , 4...20 мА. На выходе имеется релейный контакт (нормально разомкнутый) для контроля предельного значения., Сообщения о состоянии/ ошибках подаются через релейный (нормально разомкнутый) контакт., Предусмотрена возможность конфигурирования модуля при помощи стандартного программного обеспечения FDT/DTM. |
Температура в области входа | регулируется в пределах -200...+800 ℃ |
Температура хранения | -20 °C...85 °C |
Температура хранения, макс. | 85 °C |
Температура хранения, мин. | -20 °C |
Технические данные | EPLAN, WSCAD |
Тип | Реле, 1 нормально замкнутый контакт (беспотенциальный) |
Тип изделия | Преобразователь сигналов |
Тип устройства | B |
Ток I0 | 18.4 мA |
Уровень мощности | ≤ 62.5 ВA / 32 Вт (защищенная зона),≤ 16 ВA / 32 Вт (Зона 2) |
Функциональность | Программируемые переключатели, Ошибка датчика, Оконная функция |
Функция аварийной сигнализации | Отсутствует напряжение питания, Ошибка устройства |
Номер для заказа | 8965490000 |
Размеры и массы | |
Ширина | 22,5 мм |